In the case of pressure water, steel-reinforced concrete must satisfy the national standards (for ex.All characteristics mentioned in this data sheet are given for a temperature of 23 ☌, without draft and a relative rate of humidity of 50%.For sewage tanks request technical advice. mineral normal-setting waterproofing slurry weber.tec 930. Limits of use: do not use for the waterproofing of tanks with drinking water or sewage water tanks.best suited for building projects where time is at premium, particularly during the wet and cold seasons.sprayable with peristaltic pump technology and screw pump technology, e.g.resistant to water attacking concrete up to the level “highly corrosive” in accordance with DIN 4030 (up to 3.000 mg sulphate per litre of water) and also to seawater.renovation of old defective anionic bitumen-based waterproofing layers.allows waterproofing of external basement walls and facade socket areas with one product.multi-use: external and internal waterproofing / waterproofing of horizontal and vertical main surfaces / waterproofing of socket areas of facade waterproofing / horizontal waterproofing under walls / bonding layer on old bitumen layers / renovation of old defective bitumen-based waterproofing in one product.suitable on any mineral substrate; no preliminary render layer on substrate is necessary.quickly resistant to pressure water of 1.0 bar after 24 hours.weather-independent drying through reactive setting within 24 hours.allows bonding of insulation boards, drainage/protection) boards after only 4 hours.

Tec superflex full#
In addition, the product is suitable for spot-bonding and full surface-bonding of rigid-foam polystyrene boards below ground level.įor use indoors and outdoors. a powder based polymer fortified thinset in many situations / on many types of Superflex D 24 is used for external waterproofing of basement walls below ground level in new and old buildings.įor waterproofing of foundations (concrete slabs and lean concrete).įor waterproofing of working joints and butt joints between earth-contacting pre-cast water-impermeable concrete elements.įor waterproofing of water tanks (with positive water pressure up to 10 meters water head).įor waterproofing of facade socket areas as well as floor-flush window and door connection profiles.Īs horizontal damp-proof courses in walls or under ascending walls.įor retrospective internal waterproofing of earth-contacting basements walls (with negative water pressure).įor retrospective waterproofing as bondcoat and as new waterproofing on anionic defective bitumen waterproofing layers.Īs intermediate waterproofing layer under screeds, in wet-duty rooms, sanitary areas, balconies and terraces (not above heated rooms). The addition of the proper latex (liquid) from a reputable company to a bag of good thin set is usually far superior to the performance of a good polymer fortified powder thinset.įlexibility, Chemical, Shock and Vibration Resistance are better with (a real) latex fortified thinsetįor Facades, Swimming Pools and other critical applications many knowledgeable people in the tile industry strongly recommend the use of a Latex (liquid) Fortified thinset vs. If you "spray dry" or process a latex into a powder it is NO LONGER A LATEX but is now a dry, powdered polymer. There is no such thing as dried water and there is no such thing as a "powder latex" - check a dictionary.īy definition, a latex MUST be wet. I have the word “liquid” in parentheses above because it is really redundant. !Ī latex dried and turned into a powder polymer that is incorporated into a thinset is NOT the same as, and will not give the same performance of, a latex (liquid) added to a thin set adhesive/mortar. Powdered milk is NOT the same as full cream liquid milk.